Home > Error Code > Payne Furnace Error 31

Payne Furnace Error 31

Contents

All rights reserved. Turn heat up and look at furnace and it works for about 4 minutes then flame goes out and flashing code 33. Is this motor controlled or just air pressure normally? replied4 years ago. this contact form

The fact that you hear water gurgling is not a good sign. If no obstructions check the spud on the inducer where the pressure switch tubing connects, sometimes the spud will plug up. The repairman stated on the receipt it was functioning properly, but this is a rental and the tenant decided to have the Gas Co come look at it for a safety Do you get any kind of error code on the board?

Carrier Furnace Error Code 31

Reply On January 13, 2012 at 12:06 am phteo said: How to fix code 21 problem? Removed the switch and sucked on the plastic tube connected to the switch and heard a clicking noise indicating the switch was working. Payne gas furnaces are highly rated, efficient heating systems.An innovative feature of the Payne... Good tip, thanks.

Powering off the furnace and restarting would trigger the gas ignition, but it would not stay on. The outdoor air intake pipe has a screen at the furnace right where the pipe connects, the pipe would have to be pulled away to see. Thanks again, Waldon. Carrier Furnace Troubleshooting Codes It is a two stage furnace, and it doesnt seem to be kicking into the second stage to heat the place.

it looks like a rectangular 1 inch long and a pointy top. I hate calling/ paying service people. In the regular heat run cycle after 30 seconds the igniter gives error code 31. 10-26-11,09:15 PM #4 SeattlePioneer Member Join Date Jul 2007 State WA Posts 5,393 The Carrier 3-1 Reply On July 1, 2015 at 9:16 pm derrickboss said: Did you ever figure this out.

I operated the furnace with the tube to the pressure switch removed. Carrier Weathermaker 9200 Error Codes How to Read the Trouble Code Light on a Goodman Furnace How to Read the Trouble Code Light on a Goodman Furnace. ... I noticed a bit of carbon build up on the gas jets on the intake side of the burn (they look like trumpet horns) could this be a low flow gas You cannot jump it B4 the unit starts as the board needs to see an open switch or it will lockout.

Bryant Furnace Code 31

Fix is under a buck.. here i think its the spark . Carrier Furnace Error Code 31 Fill in your details below or click an icon to log in: Email (required) (Address never made public) Name (required) Website You are commenting using your WordPress.com account. (LogOut/Change) You are Bryant Plus 90 Error Code 31 Good sparkling user interface and very informative blogs.

That would make things too easy though, I suppose. 10-30-11,08:15 PM #13 mbk3 Member Join Date Dec 2004 State CAL Posts 1,483 I'm not about to get between you two, however, Is it likely to be the switch itself or something else? Using this methodology, I really didn't have to tinker with pressure switches. I hate calling/ paying service people. Bryant Furnace Pressure Switch

See my post above to "June 25, 2011 at 9:45 am david scherer" It sounds like I'm having the same problem as you. If you suspect this as the problem, try setting the fan from auto to on to cool the exchanger. test good. navigate here Pics would be great. 12-06-2008, 12:04 AM #9 thealexdexter Member Join Date: Dec 2008 Posts: 38 Rewards Points: 25 View thealexdexter's Album pic is attached of round thing...

But in minutes, hours or days it will be failing again, and it will continue to fail with a new pressure switch until the actual problem is diagnosed and corrected. Bryant Plus 80 Error Code 31 My venting is a 4" metal pipe that goes straight up to the roof. How to Troubleshoot a Payne Heat Pump How to Troubleshoot a Payne Furnace Noise.

Powered by vBulletin™ Version 4.2.3 Copyright © 2016 vBulletin Solutions, Inc.

I don't see why anyone with average mechanical skills can't replace the parts, if you can find them, but sometimes that's not enough. It read about .8 ohms...so it was letting the electricity through at room temps. Colorado Climate Control 11.490 προβολές 3:59 Carrier 58pav inducer replacement 31 pressure fault code - Διάρκεια: 3:53. Hk06nb124 You managed to hit the nail upon the highest and defined out the entire thing with no need side-effects , other people can take a signal.

still code 31. Reply With Quote « Previous Thread | Next Thread » Thread Information Users Browsing this Thread There are currently 3 users browsing this thread. (0 members and 3 guests) Tags for Clean by using turning off the furnace and blowing compressed air into the burners. his comment is here The 3 burners are going, upon start up the first fan starts, then 30sec later the igniter fires up the flames and then the fan seems to kick down a notch

Clean or replace all the filters. Payne Furnace Error... About eHow Advertise Write For eHow Contact Us Connect with us Terms of Use Report Copyright Ad Choices en-US Privacy Policy Mobile Privacy demandmedia.com © 1999-2016 Demand Media, Inc. The manual is not helpful at all.

Of course it's always possible you have a bad pressure switch. A...